In the realm of energy storage, the 12V 50Ah Deep Cycle Gel Battery emerges as a stalwart solution, offering a potent combination of reliability, longevity, and efficiency. From off-grid living to renewable energy systems, these batteries play a pivotal role in powering a wide array of applications, driving innovation and sustainability forward. Model Number:MF12V50Ah Name:12V 50Ah Sealed Lead Acid Battery Battery Type:Deep Cycle Sealed Gel Cycle Life: 50%DOD 1422 times The discharge rate: C10/C20 Warranty:3years

Send Inquiry PDF Download

12V50Ah Lead Acid Battery - Deep Cycle Gel Battery Solution

Xi'an Gaoshide New Energy Technology Co., Ltd. presents the 12V50Ah lead acid battery(Model: MF12V50Ah), a sealed lead acid battery engineered for demanding industrial environments. This deep cycle gel battery delivers 50 ampere-hours capacity at the C10/C20 discharge rate with exceptional durability. With a proven cycle life of 1,422 times at 50% depth of discharge, our battery outperforms standard flooded lead acid alternatives. The valve-regulated design eliminates maintenance requirements while maintaining reliable performance across temperatures ranging from -15°C to 50°C. Backed by a 3-year warranty, this battery serves electric mobility, renewable energy systems, and backup power applications where reliability is non-negotiable.

Understanding the 12V 50Ah Lead Acid Battery Technology

A product is made up of 6 cells in series, each of 2 volts. Each cell consists of lead dioxide positive plates and sponge lead negative plates in sulphuric acid electrolyte.

The sealed gel technology we use has many advantages over ordinary flooded batteries. Gel electrolyte reduces leakage and acid stratification. This architecture permits the user to work in any posture without risk of leakages.

The 50Ah rating means the battery will deliver 2.5 amperes for 20 hours until it drops to 10.5 volts. This medium capacity type is a bridge between small 7-12Ah devices and huge 100Ah+ industrial banks. It looks at power-to-weight efficiencies for equipment that needs to run for a long period yet can't be too heavy.

Typical internal resistance is 5-8 milliohms when fully charged. This low resistance allows high rate discharge capabilities up to 3C-5C for motor starting applications. The lead-calcium-tin alloy grids are less prone to corrosion and self-discharge is less than 3% per month at 25 °C.

product-750-750

Key Industrial Applications

Electric Mobility Solution

Wheelchairs and mobility scooters need batteries that can handle severe discharge cycles. Our battery has a range of 25-35km for typical wheelchairs. The thicker plate grids resist shedding of active material from vibration and repetitive charge-discharge cycles.

The sturdy construction is rated for 80% depth of discharge. This allows consumers to maximise their regular mobility without the risk of reducing battery life.

Solar Energy Storage System

Off-grid solar systems and street lighting systems need to cycle on a regular basis. 12V50Ah battery (Gel type) Perfect for outdoor use

The gel electrolyte has better thermal stability than AGM alternatives. It is resistant to stratification and electrolyte dry-out at high temperature. This makes it perfect for use in solar street lights in arid conditions or tropical areas.

The battery is well managed in daily charge/discharge cycles. The solar charge in the morning replaces the energy used throughout the night.

Uninterruptible Power Supply (UPS) 

These batteries are used in strings for backup power in data centers and in telecom base stations. Design life 5-10 years float. The 12V50Ah lead acid battery is held at constant voltage and is able to provide maximum power instantaneously during grid failures.

Power transfer smooth HIGH RATE DISCHARGE ABILITY The battery can deliver the short-term currents of 500A for 5 seconds without voltage breakdown. This allows for motor starts and rapid increases in load.

Marine & RV Applications

Maintenance free design & sealed is a plus for boats & leisure vehicles. The gel structure avoids acid leaks when the vehicle is in motion. Flexible installation lets you attach the unit at any angle in tight locations.

The battery powers navigation equipment, lights and auxiliary systems. Deep cycle capabilities allows you to go off-grid for extended periods without access to shore power.

Technical Specifications

Parameter
Specification
Model Number
MF12V50Ah
Nominal Voltage
12V DC
Rated Capacity
50Ah @ C20 (20-hour rate)
Battery Type
Deep Cycle Sealed Gel (VRLA)
Cycle Life
1,422 cycles @ 50% DOD
Discharge Rate
C10/C20
Internal Resistance
5-8 mΩ (fully charged)
Self-Discharge Rate
<3% per month @ 25°C
Operating Temperature (Discharge)
-15°C to 50°C
Operating Temperature (Charge)
0°C to 40°C
Float Charge Voltage
13.5V - 13.8V @ 25°C
Cycle Use Voltage
14.4V - 15.0V @ 25°C
Terminal Type
M6/M8 bolt or insert terminals
Typical Weight
14.0kg - 15.5kg
Case Material
ABS flame retardant (UL94)
Warranty Period
3 years
Compliance Standards
IEC 60896-21/22, JIS C 8702

Core Technical Advantages

Oxygen Recombination Efficiency

This is a VRLA (Valve Regulated Lead Acid) design with over 98% oxygen recombination efficiency. When charging, oxygen formed on the positive plate is consumed by recombination with hydrogen at the negative plate. This internal method eliminates maintenance and water loss.

The pressure relief valves open at exactly measured pressures (1-6 psi). This allows extra gas to vent in case of a potential overload problem, but yet maintains the seal against oxygen entry.

Extended Cycle Life Performance 

Better than standard flooded batteries is the 1,422 cycle rating at 50% depth of drain. This is due to optimised paste formulation and stronger grid construction.

Cycle life is directly affected by discharge depth. You should see 200-250 cycles at 100% DOD. The battery can reach more than 2,000 cycles at 30% DOD. This flexibility enables you to balance the needs of the runtime against the replacement expenses.

Heat Tolerance

The gel electrolyte has the steady performance at wide temperature ranges. It has a cold weather discharge capacity down to -15 deg C. This is good for exterior installations in northern areas where flooded batteries would fail.

Its high temperature tolerance prevents thermal runaway up to 50°C discharge conditions. The gel structure prevents acid evaporation and warping of the plates, problems that affect traditional batteries in hot settings.

High Rate Discharge Performance

Low internal resistance is good for instantaneous power supply. 3C-5C discharge rates are suitable for applications that need motor startup or abrupt load step.

The internal connections are made via strong inter-cell welding processes. This prevents overheating and connection failure under high current loads. The architecture enables voltage stability even at high demand periods.

Quality Control Standards

Comprehensive Testing Protocols

Every battery undergoes rigorous quality control before shipment:

Capacity Verification Testing: Full charge-discharge cycles confirm actual capacity meets the 50Ah rating within -0% to +5% tolerance. This ensures you receive specified performance.

High-Rate Discharge Validation: Testing at 3C and 5C rates verifies internal connection integrity. This prevents field failures under load conditions.

Air Tightness Inspection: Safety valve pressure testing confirms proper operation at 1-6 psi. This prevents case deformation during overcharge while maintaining oxygen exclusion.

Open Circuit Voltage Delta Analysis: After acid filling, batteries rest 7-14 days. Voltage deviations exceeding 0.05V indicate internal micro-shorts or impurities. Affected units are rejected.

Vibration Resistance Testing: IEC 60068-2-6 protocol testing ensures plate active material retention. This validates performance in mobile applications subject to constant movement.

Manufacturing Excellence

Our production facility operates under ISO 9001 and ISO 14001 certifications. Lead-calcium grid casting employs high-purity materials to minimize self-discharge. Automated plate formation ensures consistent capacity across production batches.

The manufacturing process complies with IEC 60896-21/22 stationary battery standards. Flame-retardant ABS cases meet UL94-HB or V0 specifications for fire safety.

Packaging and Logistics

Each battery is shipped in protective carton packaging with cushioning elements to prevent transit damage. Sealed construction removes shipping restrictions on flooded batteries for hazardous materials.

Standard packaging includes terminal protection covers and installation documentation. Batteries are palletised for container shipment in optimum weight distribution to avoid case stress.

We meet unique packaging requirements for OEM integration. We optimise logistics planning for bulk orders to reduce freight cost and maintain the integrity of the goods.

FAQ

Q: What charging voltage should I use for optimal performance?

A: Charging voltage depends on your application type. For cycle use in electric vehicles or solar systems, apply 14.4V-15.0V. For standby float applications like UPS systems, use 13.5V-13.8V at 25°C. Always implement temperature compensation at -3mV/°C per cell to maximize lifespan.

Q: Can I substitute a 40Ah battery with your 12V50Ah model?

A: Yes, provided the physical dimensions fit your battery compartment. The 50Ah unit provides 25% additional runtime. Verify your charger can handle the increased capacity. Small 2A chargers may require excessive charging time, potentially causing sulfation damage.

Q: How many charge-discharge cycles can I expect?

A: Cycle life correlates directly with discharge depth. At 100% depth of discharge, expect 200-250 cycles. At 50% DOD, our battery delivers 1,422 cycles. Industrial deep cycle and gel versions achieve over 800 cycles at 50% DOD.

Q: Why would a battery case swell or bulge?

A: Swelling typically results from thermal runaway caused by overcharging. Excessive charger voltage or operation in extreme heat generates gas faster than recombination valves can vent. This deforms the ABS case. Always use appropriate charge voltage and avoid high-temperature environments.

Q: What storage procedures should I follow during non-use periods?

A: Store in cool, dry locations. The product self-discharges over time. Recharge every 3-6 months or when open circuit voltage drops below 12.4V. This prevents permanent sulfation where lead sulfate crystals harden on the plates and reduce capacity.

Q: What causes premature battery failure?

A: Common failure causes include chronic undercharging, excessive discharge depth, high operating temperatures, and sulfation from prolonged storage. Following proper charging protocols and avoiding complete discharge extends operational life significantly.