Model Number: MF12V100Ah Name: 12V 100Ah Sealed Lead Acid Battery Battery Type: Deep Cycle Sealed Gel Cycle Life: 50%DOD 1422 times The discharge rate: C10/C20 Warranty: 2/3years
Send Inquiry100 Amp Lead Acid Battery - Professional Deep Cycle Power Solution
When you need reliable energy storage for mission-critical applications, our 100 amp lead acid battery delivers proven performance. Xi'an Gaoshide New Energy Technology Co., Ltd. offers the MF12V100Ah model, a 12V 100Ah sealed lead acid battery engineered with deep cycle gel technology. This battery provides an impressive cycle life of 1,422 cycles at 50% depth of discharge, making it ideal for renewable energy systems and backup power applications. With discharge rates optimized at C10/C20 and backed by a 2-3 year warranty, you get the perfect balance between capacity (100 Ampere-Hours) and durability. Weighing approximately 28-32kg, this battery offers high surge current resilience for inductive loads while maintaining 99% recyclability to meet your environmental compliance standards.

Why Choose Our 100 Amp Lead Acid Battery?
Our encapsulated gel battery solves your biggest energy storage concerns. This deep cycle version is different from a regular starter battery in that it has larger lead plates, which are specifically engineered to tolerate repeated discharge cycles.
You get high purity lead calcium tin alloy grids for low self discharge of less than 3% per month at 25 degrees Celsius. The innovative design minimises gassing and assures reliable operation in harsh environments.
The flame-retardant ABS housing (UL94-V0 standard) has very good thermal stability. This prevents thermal runaway and allows for safe operation in different temperature ranges. You receive BCI Group sizing in standard for universal installation compatibility with your existing systems.
Product Parameters
| Parameter | Specification |
|---|---|
| Voltage | 12V |
| Capacity | 100Ah |
| Dimensions | L330 × W173 × H220 mm |
| Weight | Approximately 30 kg |
| Terminal Type | M8 Bolt |
| Design Life | Up to 10 years in float service |
| Cycle Life | 1200 cycles at 50% DOD |
Primary Applications
Energy Storage Systems for Renewables
Our battery can be used for 48V solar and wind power bank for off-grid setups. Reliable power storage for rural electrification projects and distant cabins is provided by four series-connected units.
The gel structure is quite good in handling partial state-of-charge (PSoC) cycling. This makes it well suited for buffering intermittent renewable generation over daily charge-discharge cycles.
Marine & RV Power Solutions
The sealed design prevents acid spill in vibration-intensive marine settings. Stable, reliable power powers your boat or RV auxiliary systems—inverters, refrigeration, lighting and more.
The rugged construction can withstand mechanical shock from wave action and vehicle travel. You won’t have to worry about upkeep or acid leaking on your journeys.
Critical Back Up Power Systems
Our 100 amp lead acid battery is used in uninterruptible power supply systems for telecom base stations and data centers. The battery delivers high rate short duration discharge to cover utility failures until generators come on line.
This guarantees that your key infrastructure will run with 99.999% uptime reliability. You ensure uninterrupted communication services and safeguard vital data.
Performance Advantages
Longer Cycle Life
Exceptional cycle life 1,422 cycles at 50% depth of discharge . expect up to 1200 cycles at 30% DOD which is much better than typical flooded batteries.
The thick lead plates have a very good recovery after deep discharges. This resilience means a cheaper total cost of ownership for your energy storage investment.
Excellent Discharge Characteristics
The C10/C20 discharge rates are best for energy delivery for medium term applications. You can draw continuous current safely up to 50 Amps (.5C) without voltage sag or premature sulfation.
The lower the internal resistance, the easier it is to tolerate short period surge loads. It supplies the starting current needed by your inductive equipment.
Low Maintenance Requirements
With our sealed VRLA (Valve Regulated Lead Acid) technology, you skip the water addition. Just look at the terminal connections and make sure the float voltage settings are correct.
The sealed nature also guarantees no acid tracks or corrosive smells. Your installation environment is clean and safe.
Quality Control Standards
We test every product thoroughly. Our capacity is graded according to IEC 60896-21/22, each unit giving true 100Ah capacity for 20 hours.
The High Rate Discharge (HRD) test verifies surge performance. Our internal welds and inter-cell connectors are designed to safely handle 3C and 5C discharge bursts without overheating.
Air tightness testing involves detection using positive pressure helium. That verifies VRLA safety valves open at correct pressure (1-5 psi) but prevent electrolyte drying. Open Circuit Voltage (OCV) retention testing finds any micro-shorts or separator faults prior to shipment.
You obtain batteries that satisfy rigorous institutional purchasing criteria. Every unit undergoes a complete inspection before to leaving our plant.
Installation and Usage Guidelines
Correct Charging Protocol
Use a smart charger with a rating of 10-20% capacity (10A-20A). The battery will charge entirely in around 6-10 hours, most of this time in the absorption phase.
For standby application float voltage set between 13.6V-13.8V. For cycle use, set to 14.4V-15.0V throughout bulk and absorption stages.
Discharge Best Practices
Avoid draining routinely below 50% of capacity. This will greatly improve your return on investment and greatly increase the cycle life.
Keep continuous discharge below 0.5C (50 Amps). Higher rates create voltage sag and speed up plate sulfation.
Parallel and Series Connections
Higher voltage systems can be achieved by connecting many batteries in series. Four 12V units make up a conventional 48V bank for renewable energy applications.
Use only the same age batteries of the same make in parallel. Batteries that don’t match produce parasitic loads. The stronger batteries repeatedly charge the weaker batteries, and this causes premature failure.
Get Your Reliable Power Solution Today
Ready to tackle your energy storage challenges? Our product delivers the reliability and performance your applications expect. No matter what your needs for renewable energy systems, marine power upgrades or crucial backup power, we have the answer.
If you want to get personalised advice, please contact our technical staff at admin@gaoside.com. We’ll partner with you to develop the appropriate battery system for your application.
FAQ
Q: What is the expected lifespan of this battery?
A: In float service applications like UPS systems, expect 3-5 years of reliable performance. For deep cycle applications such as solar energy storage, lifespan depends on depth of discharge—typically 400-600 cycles at 50% DOD.
Q: How long does charging take?
A: Using a standard smart charger at 10A-20A, full charging requires 6-10 hours. The absorption phase takes the longest time to ensure complete saturation without overheating the cells.
Q: Can I mix different battery brands in my system?
A: Professional guidance strictly advises against this practice. Differences in internal resistance and chemistry age create parasitic loads. The stronger battery constantly charges the weaker one, causing premature failure of your entire battery bank.
Q: What's the maximum safe discharge current?
A: While the battery can handle higher surge currents, continuous discharge should stay below 0.5C (50 Amps). This prevents voltage sag and plate sulfation. Regular discharge below 50% capacity maximizes your investment.
Q: Does this sealed battery require maintenance?
A: It's maintenance-free regarding water addition due to VRLA technology. However, you should check terminal torque, keep connections clean to prevent tracking currents, and perform periodic equalization charges if manufacturer approved.
Q: What certifications does this battery hold?