1. Small Internal Resistance 2. More Better Quality, More Better Consistency 3. Good Discharge, Long Life 4. Low temperature resistant 5. Stringing Walls Technology Will Transport Safer.

Send Inquiry PDF Download

12V150Ah Lead Acid Battery – Reliable Energy Storage for Industrial & Commercial Use

At Xi'an Gaoshide New Energy Technology Co., Ltd., we specialize in delivering high-performance 12V150Ah lead acid battery designed for demanding applications. Our batteries feature small internal resistance (below 4.5mΩ when fully charged), ensuring superior discharge efficiency and extended service life. Built with high-purity lead (99.997%) and advanced Lead-Calcium-Tin alloy grids, these maintenance-free VRLA batteries deliver consistent 150Ah capacity at C10 rate. Weighing approximately 42-47kg with dimensions of 483mm × 170mm × 240mm, they perfectly balance energy density and portability. With a design life ranging from 5-8 years for AGM variants to 12 years for Deep Cycle Gel models, our batteries meet IEC 60896-21/22 and UL1989 standards for maximum safety and reliability.

product-1080-1299

What Makes Our 12V150Ah Battery Different?

Our battery is the sweet spot between consumer grade units and huge industrial cells. This is a secondary energy storage device consisting of six 2 volt cells connected in series utilising Valve Regulated Lead Acid (VRLA) technology.

The 150Ah rating signifies actual world performance. Your system can provide 15 Amps for 10 hours continuous or 7.5 Amps for 20 hours before the voltage falls below the 10.5V cut-off level. This type of capacity is intended to address your critical pain points.

We developed this solution for applications where lithium-ion is cost prohibitive and traditional flooded batteries are too maintenance intensive. Maintenance-free operation is provided by the AGM or Gel technology variants. Water topping is eliminated by the sealed design, saving you a lot of operational expenditures.

Our batteries are based on innovative Stringing Walls Technology, which makes transit safer and installation easier. You will see the difference in quality consistency with every unit we provide.

Three High-Demand Applications Where Performance Matters

Renewable Energy Storage Systems

You need reliable storage for your off-grid solar/wind systems. Our batteries are particularly suitable to 24V or 48V bank applications where daily charge-discharge variations are coupled with robust deep-cycle performance. You keep the steady output performance even during low irradiance periods.

Backup Power for Data Center & Telecom

Base Transceiver Stations located in remote areas are fed by unsteady grid electricity. Our high-rate discharge capability allows instant load transfer during outages with no voltage sag. Critical bridge power protects your delicate switching equipment when it matters most.

Marine & RV Use

Vibration and humidity are issues in marine conditions. Our heavy-duty units are equipped with reinforced ABS containers and vibration-resistant plate grouping. They are reliable home banks, providing power for navigation systems, refrigeration and lighting where there is no shore power.

product-750-750

Parameters

Cell Per Unit 6
Voltage Per Unit 12V
Capacity 150AH@10hr-rate to 1.80V per cell @25°c
Weight 41KG
Max. Discharge Current 1000 A (5 sec)
Internal Resistance 3.5 M Omega
Operating Temperature Range Discharge: -40°c~50°c
Charge: 0°c~50°c
Storage: -40°c~60°c
Normal Operating 25°c±5°c
Float charging 13.6 to 14.8 VDC/unit Average at 25°c
Recommended Maximum Charging Current 15 A
Equalization 14.6 to 14.8 VDC/unit Average at 25°c
Self Discharge Batteries can be stored for more than 6 months at 25°c. Self-discharge ratio less than 3% per month at 25°c. Please charge
batteries before using.
Terminal Terminal F5/F11
Container Material A.B.S. UL94-HB, UL94-V0 Optional

Superior Quality Through Advanced Manufacturing

Advanced Plate Technology

We employ thicker plates with a better active material density. This design decision will directly affect how well your battery discharges and its overall lifespan. You will have better low temperature resistance than what is sold on the market.

Precision Grid Castings

Our Lead-Calcium-Tin alloy grids reduce corrosion and water loss. This means less self discharge and a longer standby life. Your battery will hold its charge even if you leave it unused for a long time.

Strict Quality Control

All units are fully graded before being shipped. Furthermore, high-rate discharge tests are performed to evaluate the integrity of the internal busbars and the welding quality. Our helium leak detection guarantees case sealing and accurate safety valve pressure calibration.

Open Circuit Voltage uniformity between batches is within .05V variation. This is a big deal when you're creating 12V150Ah lead acid battery banks for crucial applications.

Understanding Key Performance Factors

How Temperature Impacts Your System

Temperature has a great impact on the performance and longevity of a battery. Corrosion increases with temperature and battery life is halved for every 10°C rise above 25°C. At 0°C, however, you will only get about 85% of the rated 150Ah capacity.

Plan your installation with temperature regulation in mind.  Good ventilation and climate management is a great protection for your investment.

Discharge Depth Considerations

The depth of your discharge has a big impact on the cycle life. The standard AGM types provide 400 to 600 cycles at a 50% depth of discharge. Deep Cycle Gel variants reach 800-1200 cycles at similar DOD.

Repeatedly going above 80% DOD will drastically reduce service life. Design your system with the right capacity headroom for maximum lifespan.

Correct Charge Parameters

Cycle charge voltage 14.4V-14.8V, float charge voltage 13.5V-13.8V. Maximum charging current is not more than 37.5A for 150Ah unit. Sticking to these settings will ensure safe functioning and a max lifespan.

Storage and Maintenance Best Practices

Keep your battery completely charged and store it in a cool, dry place. The charge has to be refreshed every 3 to 6 months because to self-discharge. - Never allow voltage to go below 10.8V . This results in irreversible sulfation that permanently ruins capacity .

Keep the terminals clean and the connections tight. Periodically check the case for bulging or cracks. Just watch the voltage especially if you have a battery bank setup.

Our VRLA architecture is maintenance-free but it is prudent to monitor often to spot any possible problems before they become problems. The service life is greatly extended by simple preventive actions.

Why Partner With Gaoshide?

We are experts in renewable energy and we offer our experience to your projects. Our technical staff can give professional consultation to your project from the initial system design to commissioning and operation.

You receive solutions designed for your needs. If common setups do not meet your demands, we may build a custom battery system for you.

We are committed to quality through careful control of production and ongoing improvement. Each battery is manufactured to satisfy international safety standards and has been subjected to rigorous testing before being shipped to you.

We promote the global shift to renewable energy through sustainable technological innovation. With Gaoshide, you are dealing with a company committed to your long-term success.

FAQ

Q: How long will the battery actually last in my application?

A: Realistic cycle life depends on your Depth of Discharge. At 50% DOD, expect 400-600 cycles from AGM models and 800-1200 cycles from Deep Cycle Gel variants. Shallower discharge cycles extend this considerably, while deeper discharges reduce it.

Q: Can I mix new batteries with older ones in my system?

A: Never connect new and old batteries in parallel or series. Voltage differences and internal resistance mismatches cause the new battery to discharge into the old one. This parasitic load leads to overheating and premature failure of your new unit.

Q: What charging equipment do I need?

A: Use a quality charger designed for VRLA batteries with proper voltage regulation. For cycle use, set to 14.4V-14.8V; for float/standby use, set to 13.5V-13.8V. Temperature compensation features help optimize charging in varying ambient conditions.

Q: How does cold weather affect performance?

A: Cold temperatures reduce available capacity. At 0°C, expect around 85% of rated capacity. At -20°C, this drops further. However, cold temperatures also slow degradation processes, so batteries in cooler climates often outlive those in hot environments despite reduced instantaneous capacity.

Q: What maintenance does a sealed battery require?

A: Our VRLA design eliminates water topping requirements. However, you should periodically check terminal tightness, monitor voltage levels, and ensure proper charging parameters. Keep the battery clean and verify that safety valves aren't obstructed.