120ah lead acid battery
Model Number: MF12V100Ah Name: 12V 100Ah Sealed Lead Acid Battery Battery Type: Deep Cycle Sealed Gel Cycle Life: 50%DOD 1422 times The discharge rate: C10/C20 Warranty: 2/3years
Send Inquiry120Ah Lead Acid Battery - Professional Deep Cycle Power Solution
At Xi'an Gaoshide New Energy Technology Co., Ltd., we specialize in delivering high-performance 120ah lead acid battery solutions engineered for demanding power applications. Our MF series 12V 100Ah sealed lead acid battery represents proven deep cycle gel technology, offering exceptional reliability for your energy storage needs. With a robust cycle life of 1,422 cycles at 50% depth of discharge and discharge rates optimized at C10/C20, our batteries deliver consistent performance you can depend on. Each unit is backed by our 2-3 year warranty commitment, ensuring your investment is protected.
Our product systems provide approximately 1.44 kWh nominal energy capacity, bridging the gap between standard consumer units and heavy industrial blocks. Whether you're powering telecom infrastructure, renewable energy systems, or backup power installations, our sealed gel technology offers the perfect balance of energy density and practical handling.

Why Choose Our 120Ah Lead Acid Battery Solutions?
Enhanced Cycle Performance
Our sealed gel technique offers excellent deep discharge performance. Your system features innovative plate design for dramatically longer service life than typical flooded batteries. Deep cycle architecture ensures reliable power delivery under heavy load conditions.
Each cell is provided with lead-calcium-tin grid alloys to reduce water loss. This engineering decision lowers maintenance requirements and increases shelf life. Your operations keep functioning with little or no intervention required.
Optimized for Critical Infrastructure
Telecom base stations need to be consistently reliable during grid outages. Our batteries provide you the precise time needed for the bridge, generally 30 to 90 minutes of high amperage run time. This allows your backup generators to come online seamlessly without interruption of service.
Our product banks are great for renewable energy systems including off-grid solar and wind applications. They deal with the charge-discharge cycling that is typical of variable renewable sources. Whether the weather is good or bad, your energy storage system works efficiently.
Building Standards in Strict
Each unit is constructed in rugged ABS containers that meet UL94 flammability requirements. So, it guarantees safety in various installation environments. Heavy-duty copper insert terminals reduce contact resistance for reliable power output under load.
Our quality control procedures check the actual capacity supply at given discharge rates. You get batteries that really provide the goods. Weight verification ensures proper lead plate composition, directly effecting the longevity you anticipate.
Thermal Resistance
The operating environments vary widely from application to application. Our batteries are reliable from -15°C to 50°C. This wide temperature tolerance makes them suited for both interior controlled situations and outdoor installations exposed to the weather.
The sealed gel electrolyte remains stable even under high-heat conditions. Your telecom shelters and solar installations are still doing their thing without the need for thermal deterioration worries.
Product Parameters
| Parameter | Specification |
|---|---|
| Nominal Voltage | 12V |
| Capacity | 120Ah |
| Dimensions | 330 × 173 × 220 mm |
| Weight | 32.5 kg |
| Terminal Type | M8 Bolt |
| Design Life | Up to 12 years |
| Cycle Life | 1200 cycles at 50% DOD |
Key Applications Across Industries
Energy Storage Systems for Renewable Energy
Reliable energy banking for off-grid systems. Our 48V installations (four 12V units in series) provide vital night-time load support for solar systems. Lead acid chemistry is fail-safe, which is good for remote areas.
The patterns of charge of wind energy systems are vary The product takes these variations in stride. Your renewable investment provides continuous power, regardless of the intermittency of generation.
Telecommunications & UPS Back-up
Base transceiver stations do not allow for down time. Our batteries have the surge current capability to activate communication equipment. Your network stays online when the grid goes crazy.
Accurate runtime estimations for data center UPS systems are a must. 120Ah capacity enables consistent backup time for essential server loads. Your IT infrastructure will not be affected by changes in power.
Marine and Mobility Solutions
Marine house banks should be resistant to vibration. Our AGM technology eliminates the shedding of plates due to the continual movement of the vessel. On voyages your onboard systems receive stable electricity.
For electric mobility equipment such as floor cleaners and industrial trucks, tolerance to deep discharge is an advantage. Performance doesn't drop down as fast as traditional batteries during cycling. Working shifts your efficiency is the same.
Charging & Maintenance Best Practices
Best Charging Conditions
Proper charging greatly enhances battery life. Charging currents should be between 12A and 24A (0.1C to 0.2C rate). This range gives maximum plate life and avoids thermal problems.
Temperature adjustment is important for charging voltage. If greater ambient temperatures exist, lower the charging voltage slightly to prevent overcharging. Battery management system should take into account environmental circumstances.
Storage Directions
Protocols are required for extended storage. Always charge the batteries fully before putting them into storage to prevent sulfation. Keep your plate in good condition by topping up every 3-6 months when idle.
Ideal: Temperature regulated storage environments Store in cool, dry places out of direct sunlight. It’s time to launch, and your inventory is ready for peak performance.
Things to Consider When Configuring a Bank
Do not combine batteries from different manufacture lots. Uneven charging across the bank due to resistance mismatches. This leads to premature failure of the weaker cells and overcharging of the others.
If you are expanding current systems, replace whole banks rather than add new units to old ones. Your system is balanced for performance and overall maximum life.
Quality Assurance & Testing Protocols
Rigorous Inspection Standards
Every 120ah lead acid battery undergoes comprehensive capacity grading tests. We verify actual 120Ah delivery at specified C20 discharge rates. This eliminates the common industry practice of mislabeling lower-capacity units.
High-rate discharge testing subjects batteries to 3C and 5C current loads. These short-duration stress tests confirm internal construction integrity. Your batteries arrive ready for demanding real-world applications.
Seal Integrity Verification
VRLA valve testing ensures proper recombination efficiency. Pressure testing confirms no electrolyte leakage occurs during operation or transport. Your installations remain clean and safe throughout the service life.
Open circuit voltage consistency checks guarantee bank balance. We maintain strict ±0.05V tolerances across units. Your series and parallel configurations perform uniformly without cell imbalance issues.
Certification Compliance
Our manufacturing processes adhere to IEC 60896-21/22 international standards. This ensures compatibility with global equipment specifications. Your procurement decisions align with recognized industry benchmarks.
Weight verification confirms adequate lead content in every unit. This directly impacts the cycle life and capacity retention you experience. Your investment delivers the value promised in technical specifications.
Packaging & Logistics
Our batteries ship in reinforced corrugated cartons with protective corner bracing. Each unit is individually wrapped to prevent terminal contact during transport. Palletized shipments accommodate your bulk ordering needs efficiently.
We provide detailed handling instructions with every order. Proper lifting techniques prevent case damage and internal component stress. Your receiving teams can safely process shipments without specialized equipment.
Custom packaging solutions are available for international shipping requirements. We accommodate your specific logistics needs including hazmat documentation and multi-modal transport considerations.
FAQ
Q: What charging current works best for extending battery life?
A: Use charging currents between 12A and 24A for optimal results. This 0.1C to 0.2C rate balances charge speed with thermal management. Higher currents accelerate charging but reduce overall cycle life through increased heat generation.
Q: How does cold weather affect my 120Ah battery capacity?
A: At 0°C, available capacity typically drops to approximately 85% of rated capacity. Chemical reactions slow in cold temperatures, reducing effective power delivery. Plan for this derating in outdoor winter applications to ensure adequate backup time.
Q: Can I replace just one battery in an existing bank?
A: We strongly advise against mixing old and new batteries. Resistance differences cause the new unit to undercharge while old units overcharge. Always replace complete banks to maintain balanced performance and prevent premature failures.
Q: What's the difference between Gel and AGM versions?
A: AGM technology excels in high current burst applications like UPS systems. Gel variants perform better in slow, deep discharge scenarios with high ambient temperatures. Choose based on your specific load profile and environmental conditions.
Q: How often should I perform maintenance checks?
A: Sealed batteries require minimal maintenance compared to flooded types. Check terminal connections quarterly for corrosion. Monitor voltage across the bank monthly to catch imbalance early. Your system benefits from these simple preventive measures.
Q: What causes permanent capacity loss in lead acid batteries?
A: Sulfation is the primary culprit—when batteries remain in discharged states, lead sulfate crystals harden. This irreversibly damages plates and destroys capacity. Maintain proper float charging or periodic top-up charging to prevent this degradation.
Contact Us Today
Ready to power your critical applications with 120ah lead acid battery? Email us at admin@gaoside.com for technical specifications, volume pricing, or custom solution design.
Quick Links


















