Home > Products > Lead acid battery > large lead acid battery
large lead acid battery

large lead acid battery

Model Number: MF12V250Ah Name: deep cycle 12V 250ah battery Battery Type: Deep Cycle Sealed Gel Cycle Life: 50%DOD 1422 times The discharge rate: C10/C20 Warranty:2/ 3years

Send Inquiry

 Large Lead Acid Battery - Industrial Grade Deep Cycle Power Solution

At Xi'an Gaoshide New Energy Technology Co., Ltd, we specialize in delivering reliable industrial energy storage solutions. Our large lead acid battery model MF12V250Ah represents professional-grade power for demanding applications. This deep cycle sealed gel battery features 250Ah capacity at 12V configuration, engineered for sustained performance with 1422 cycles at 50% Depth of Discharge (DOD).

The C10/C20 discharge rate ensures consistent power delivery across various load conditions. Your operations benefit from our 2-3 year warranty coverage, backed by strict quality control procedures. Whether you need backup power, renewable energy storage, or industrial equipment power supply, this battery delivers dependable performance where it matters most.

Understanding Deep Cycle Battery Technology

Deep cycle batteries differ fundamentally from standard automotive batteries. They're designed for repeated discharge and recharge cycles rather than short bursts of starting power.

Our sealed gel construction eliminates maintenance requirements completely. You won't need to add water or check electrolyte levels. The gel electrolyte technology immobilizes sulfuric acid within silica gel, preventing leakage even if the case becomes damaged.

This design makes our batteries safer for indoor installations. They operate without releasing harmful gases during normal charging. Your facility gains flexibility in placement options without dedicated ventilation infrastructure.

The sealed valve-regulated design maintains optimal internal pressure automatically. This extends service life while reducing your operational costs significantly.

Product Parameters

Parameter Specification
Voltage 2V, 6V, 12V options available
Capacity 100Ah–3000Ah
Design Life Up to 20 years
Operating Temperature -20°C to 55°C
Self-discharge Rate <3% per month at 20°C

Key Advantages for Industrial Applications

Superior Durability

We are using thick lead-calcium-tin alloy grids in our batteries which are highly resistant to corrosion. This design makes it dependable for extended periods of time in hostile conditions.

Rugged design withstands mechanical shock and vibration. Your equipment functions dependably in mobile and industrial environments with continuous motion.

Maintenance-Free Operation

The sealed gel technology eliminates all the normal maintenance chores. You lower labour expenses and eliminate production delays for battery service.

No water topping is needed during the whole service life. Core operations, not battery maintenance, is your team's priority.

The pressure inside the self-regulating valve system is automatically controlled. This prevents overcharging damage and ensures the best performance.

Affordable Energy Storage

Lead acid technique has the lowest cost per kilowatt-hour for stationary applications. The first investment you make has the highest worth of all alternative technologies.

Huge energy reserves with 12V setup thanks to the 250Ah capacity. That is approximately 3 kilowatt hours of stored energy for your critical systems.

Replacement parts and service support are accessible worldwide. You get proven infrastructure and competitive pricing over the battery lifecycle.

Thermal Management Simplicity

High thermal heat capacity simplifies cooling requirements significantly. Your installation avoids complex HVAC systems often necessary for lithium alternatives.

The large lead acid battery operates reliably across wide temperature ranges. From cold storage facilities to warm industrial environments, performance remains consistent.

This thermal stability reduces infrastructure costs substantially. You install batteries where needed without expensive environmental control systems.

Industrial Applications

Renewable Energy Storage Systems

Solar and wind systems need good buffering of energy. During high output times, we put extra generation into our batteries.

Its deep cycle architecture is optimised for effective daily charge discharge cycling. Your renewable system is working all the time, whatever the weather.

These batteries are used for peak shaving applications in grid linked systems. You cut demand charges by pulling power from storage during peak hours.

Backup Power for Telecommunications

Network infrastructure needs to be operational 24/7. Battery backup is instant when grid power goes off.

The fast rate-of-discharge capability swiftly backs up important loads. While generators start and synchronise your systems remain connected.

Float charging stability means being prepared for crises. Batteries will not deteriorate and retain full capacity for long durations when not in use.

Material Handling Equipment

Reliable Motive Power Forklifts & Industrial Vehicles It's 250Ah capacity means it can be used for a long time between charging cycles.

Sealed construction prevents acid spillage in your building. Your equipment continues to run on multi-shift schedules, and your workplace is safer.

The weight of the battery is a good counterweight for lifting tasks. This dual capability enhances vehicle performance and stability.

Emergency Lighting & Security Systems

Critical safety systems must have guaranteed power. If the power goes out, our batteries guarantee your emergency lighting.

There are security cameras, controls for access and alarm systems working 24/7. Your facility is protected without interruption.

The lengthy float life means it has to be replaced less often. You cut lifespan costs and meet code compliance for safety systems.

Installation and Operating Guidelines

Placement Factors

Install batteries in well ventilated areas even with sealed structure. This measure keeps the device within ideal working temperatures.

Keep away from direct sunshine and heat. Extreme temperatures might limit performance and prematurely degrade service life.

Be certain the mounting surface will hold the weight of the battery equally. The right support prevents case damage and keeps internal components intact.

Charge Parameters

Use chargers designed for sealed gel batteries. Wrong charging profiles cause irreparable damage to the battery.

Maintain float charge voltage at 13.5V to 13.8V at 25°C. This range ensures full charge without the stress of overcharging.

Temperature compensation Automatically adjusts voltage for ambient conditions. Your system keeps perfect charge with seasonal changes.

Safety Policies

When handling batteries, always wear safety equipment. Construction is sealed, but with sufficient measures there are no mishaps.

Avoid short circuits by installing with insulated tools.  If the terminals accidentally touch, there’s a deadly spark and harm may be done.

Disconnect charging sources before maintenance. This basic precaution prevents electrical dangers during service.

Why Choose Gaoshide Large Lead Acid Battery Solutions?

We have several years of experience in renewable energy and energy storage systems. We understand your operational needs and give workable solutions.

Each battery undergoes extensive quality control testing before it is shipped. You get goods that meet international standards including IEC 60896 for stationary cells.

Technical assistance is included with every purchase for the life of the product. Our engineering team may assist with size, installation advice, troubleshooting, as needed.

Special application needs can be met with custom configurations. We tailor voltage, capacity and physical sizes to your unique requirements.

Worldwide shipping means on-time delivery no matter where you are. We work with trusted logistics partners to ensure your batteries are delivered safely and efficiently.

FAQ

Q: How long does the battery last in typical applications?

A: With proper charging and operating within recommended parameters, you can expect 1422 cycles at 50% depth of discharge. In standby applications with float charging, the battery typically provides 8-12 years of service life depending on environmental conditions and maintenance practices.

Q: Can I connect multiple batteries for increased capacity?

A: Yes, you can configure batteries in parallel for higher capacity or series for increased voltage. When connecting multiple units, ensure all batteries are the same age, model, and state of charge. This prevents imbalanced charging that reduces overall system performance.

Q: What's the difference between gel and AGM technology?

A: Gel batteries use silica to immobilize the electrolyte into a gel-like substance, while AGM uses absorbent glass mat separators. Gel batteries typically offer better deep discharge recovery and longer life in cyclic applications. They also perform better in high-temperature environments.

Q: Do I need special charging equipment?

A: Yes, sealed gel batteries require chargers with specific voltage profiles. Standard flooded battery chargers may overcharge and damage gel batteries. We recommend using smart chargers with gel battery settings and temperature compensation for optimal results.

Q: How do I know when the battery needs replacement?

A: Monitor capacity degradation over time. When the battery can no longer deliver 80% of its rated capacity, or if it cannot maintain float voltage properly, replacement becomes necessary. Regular capacity testing helps you plan replacements before unexpected failures occur.

Q: What disposal procedures should I follow?

A: Lead acid batteries contain recyclable materials but require proper handling. Contact authorized recycling facilities that process lead acid batteries. Never dispose of batteries in regular waste. Most regions have regulations requiring professional recycling to recover lead and plastic components safely.

Contact Us for Your Power Storage Needs

Ready to implement reliable energy storage for your operations with large lead acid battery? Email us at admin@gaoside.com to discuss your project today.

Quick Links

Any questions, suggestions or inquiries, contact us today! We're happy to hear from you. Please fill out the form below and submit it.