Home > Products > rock- mounted type lithium battery > Rack-mounted lithium battery10.24kWh
Rack-mounted lithium battery10.24kWh

Rack-mounted lithium battery10.24kWh

Nominal voltage: 51.2V
Rated capacity: 100Ah
Charge cut-off voltage: 54V
Discharge cut-off voltage: 39/42V
Communication method: RS485/CAN
Size: 442*420*266mm
Weight: 88kg

Send Inquiry

Rack-Mounted Lithium Battery10.24kWh - Professional Energy Storage Solution

At Xi'an Gaoshide New Energy Technology Co., Ltd., our Rack-mounted lithium battery10.24kWh is engineered specifically for professional energy storage applications. This enterprise-grade system features a nominal voltage of 51.2V and a rated capacity of 100Ah, delivering precisely 10.24kWh of reliable power. Built with advanced LiFePO4 prismatic cell architecture, it offers exceptional cycle life exceeding 6,000 cycles at 80% DOD.

The compact design measures 442×420×266mm and weighs just 88kg, making it perfect for standard 19-inch rack integration. With charge cut-off voltage at 54V and discharge cut-off at 39/42V, you get precise power management. The integrated Battery Management System (BMS) supports both RS485 and CAN communication protocols, enabling seamless integration with modern inverter systems and remote monitoring capabilities.

product-1-1

What Makes This Battery Different?

Traditional lead-acid batteries are becoming obsolete in demanding commercial environments. Our product solves critical industry challenges that businesses face daily.

Space Efficiency Matters

Your server room space is expensive. This battery fits standard 19-inch cabinets, occupying just 4U to 5U height. You can achieve high-density energy storage without wasting valuable real estate.

Intelligent Communication

Gone are the days of "dumb storage." The integrated BMS actively communicates with your inverter via CAN/RS485 protocols. You get real-time State of Charge (SOC) monitoring, precise depth of discharge management, and remote SNMP monitoring capabilities.

Thermal Stability You Can Trust

LiFePO4 chemistry provides superior thermal stability compared to other lithium technologies. The system operates reliably across -20°C to 55°C, handling temperature fluctuations that would compromise lesser batteries.

Technical Specifications

Parameter
Value
Nominal Voltage
51.2V
Rated Capacity
100Ah
Total Energy
10.24kWh
Cell Chemistry
LiFePO4 (Lithium Iron Phosphate)
Charge Cut-off Voltage
54V
Discharge Cut-off Voltage
39V/42V
Max Continuous Discharge Current
100A - 150A
Cycle Life
>6,000 cycles @ 80% DOD
Operating Temperature (Discharge)
-20°C to 55°C
Dimensions
442mm × 420mm × 266mm
Weight
88kg
Gravimetric Energy Density
130-160 Wh/kg (pack level)
Communication Protocol
RS485 / CAN
Protection Features
Over-voltage, Under-voltage, Short-circuit, Thermal runaway
Service Life
10-15 years
Compliance Standards
UL1973, IEC62619, UN38.3

Real-World Applications

Telecom Base Stations and Data Centers

Downtime costs thousands a minute in mission essential environments. This battery is a better UPS alternative than VRLA batteries. Due to its standard rack structure, direct installation in existing server cabinets is possible.

You are guaranteed 99.999% uptime during power outages. Smaller foot print vs standard batteries gives you more room for your real infrastructure. With remote monitoring, your team may take action before a problem becomes a bigger problem.

Energy Storage Commercial and Industrial

Small to medium firms are reaping big savings from peak shaving. Build 100kWh+ systems by stacking 10 units in parallel that modify your energy use patterns.

The high C-rate capacity means you can accurately release stored solar power when tariffs are at their highest. Strategic load shifting cut operating costs by 20-40% for many businesses.

Hybrid Solar Systems for High-End Residential

Large residences off-grid or hybrid need solid energy options. Often a single 10.24kWh module anchors complicated residential systems perfectly.

Your garage goes from hot to cold and back again with the seasons. This battery handles variances without loss of performance It works flawlessly with major inverter brands like as Victron, Deye and Growatt. You can use it to reliably power massive inductive loads such as HVAC and pumps through the night.

Quality Control Standards

Quality is not accidental. Our production process is built around what matters most to professional buyers.

Cell Consistency Verification

Each cell is sorted with care. We guarantee internal resistance variances of less than 0.5mΩ and voltage differences of less than 5mV inside each pack. This prevents the “barrel effect” of one weak cell limiting the capacity of your whole system.

BMS Protocol Test

Communication failures add to service costs. We check for correct handshake with common inverters prior to dispatch. No bogus SOC measurements or weird communication failures will be seen.

Environmental Stress Testing

Your battery will be put to the test. We expose devices to high temperature ageing at 45°C and vibration testing simulating rugged transport circumstances. This provides busbar welding structural stability under stress.

Safety Function Verification

In fact we actually fire protection measures during testing. Short-circuit and over-temperature protection MOSFETs have to switch off power in milliseconds. The entire installation is protected by IEC62619 safety requirements.

Parallel Configuration & Scalability

Your energy needs grow over time. This Rack-mounted lithium battery10.24kWh system scales with your requirements.

Start with a single unit for 10.24kWh capacity. Add up to 15-16 units in parallel configurations for systems exceeding 163kWh. The intelligent BMS manages load balancing across all connected units.

Important Configuration Note

Always use batteries from consistent manufacturing batches. Mixing different batches creates impedance mismatches that cause circulating currents. This degrades your newer batteries prematurely and reduces overall system efficiency.

For installations beyond 16 units, consider an external combiner hub. This maintains optimal performance while protecting your investment through proper current distribution.

FAQ

Q: Can I parallel multiple batteries from different manufacturing batches?

A: We advise against mixing batches. Different batches may have impedance variations that cause circulating currents between units. This degrades newer batteries faster than expected. Always use batteries with consistent firmware versions and manufacturing dates. For optimal performance, limit parallel configurations to 15-16 units without an external combiner hub.

Q: How does the BMS handle cold weather charging?

A: The BMS includes intelligent low-temperature cutoff, typically activated below 0°C. Charging LiFePO4 cells below freezing causes lithium plating, which permanently damages cell structure. Advanced units feature integrated heating films that automatically warm cells before enabling charge cycles. This protects your investment in harsh winter climates.

Q: What voltage settings should I use without communication cables?

A: For the standard 16-cell 51.2V architecture, set your inverter's Bulk/Absorption voltage to 56.0V-56.8V. Configure Float voltage at 54.0V. These settings allow proper cell balancing without triggering over-voltage protection. However, we strongly recommend using communication cables for optimal performance and battery longevity.

Q: What depth of discharge should I plan for maximum lifespan?

A: While rated for 100% DOD, industry best practice recommends 80-90% DOD operation. This ensures you reach the rated 6,000+ cycle life. Constant 100% discharge accelerates capacity degradation. Plan your system sizing accordingly to maintain this operational window for maximum return on investment.

Q: Will this work with my existing 48V inverter?

A: Yes, the 51.2V (16S) battery is compatible with 48V systems. Your inverter's operating voltage window must extend to 58V or 60V maximum. You'll need to adjust the inverter's high-voltage cutoff settings to prevent nuisance tripping during final charging stages. Check your inverter specifications or contact us for compatibility verification.

Q: How do I maximize the 10-15 year service life?

A: Operate within 80-90% DOD range consistently. Maintain ambient temperatures between 15-35°C when possible for optimal performance. Ensure proper ventilation around rack installations. Use communication protocols for active BMS monitoring. Perform annual system checks including connection torque verification. These practices help you achieve the full rated service life.

Q: What happens if one battery in my parallel bank fails?

A: The BMS in each unit operates independently. A failing unit will disconnect itself through internal protection mechanisms. Your remaining batteries continue operating normally. However, you should replace the failed unit promptly. Operating with mismatched capacities reduces overall system efficiency and can stress remaining units.

Ready to Upgrade Your Energy Storage?

Our Rack-mounted lithium battery10.24kWh delivers the reliability, scalability, and performance your project demands. Contact our technical team at admin@gaoside.com for detailed specifications, compatibility verification, or custom configuration assistance.

Quick Links

Any questions, suggestions or inquiries, contact us today! We're happy to hear from you. Please fill out the form below and submit it.